Menú

Filtros

HemoCue Hb 201+ Hemoglobin System

HemoCue Hb 201+ Hemoglobin System

IMPORTANT NOTICE:

Our website is scheduled for routine maintenance and will be unavailable from Friday, April 4th at 9:00 PM ET. through Saturday, April 5th at 12:00 PM ET.
HemoCue

Learn More about the HemoCue® Hb 201+ System

The HemoCue® Hb 201+ System is a trusted point-of-care testing device designed to deliver lab-quality hemoglobin results quickly and efficiently. This system empowers doctors and medical professionals with immediate, reliable data to make informed decisions, all within the patient’s visit. Below, we’ll explore key benefits, product specifications, and more.

Hb 201+ System

Hb 201+ Microcuvettes


Key Benefits of the HemoCue® Hb 201+ System

Fast Results

Receive lab-accurate hemoglobin results in less than a minute, allowing for prompt treatment decisions while the patient is still present.

Easy Operation

The device is designed to be user-friendly, making it accessible even to non-laboratory personnel.

Built-In Quality Control

A self-test function ensures consistent accuracy, reducing the risk of errors and enhancing confidence in results.

Data Storage

The system can store up to 600 test results, complete with date and time, for easy tracking and record-keeping.

Sample Flexibility

Accepts capillary, venous, or arterial whole blood, offering flexibility in different medical scenarios.

Connectivity

Compatible with printers and other devices, offering options for data transfer via Bluetooth® through HemoCue® BT Connect, making it ideal for modern clinical settings.


How to Set up the Hb 201+ System

Setting up your HemoCue® Hb 201+ System is quick and straightforward. Follow these steps to get started:

Startup Process:

  1. Place the analyzer on a stable, horizontal surface.
  2. Connect the power adapter or insert four AA (1.5V) batteries.
  3. Pull the cuvette holder out to the loading position.
  4. Press the left button until all symbols appear on the display.
  5. The analyzer will perform a self-test. Once complete, three flashing dashes indicate it is ready for use.

Setting Up Audio & Date/Time:

  1. Enter setup mode by pressing both buttons until the QC symbol flashes.
  2. Press the right button until the audio symbol appears.
  3. Press the left button to activate or deactivate the sound.
  4. Continue pressing the right button until the time, year, and date settings appear.
  5. Adjust the hour using the left button, then press the right button to move to the next character.
  6. Repeat this process for the remaining date and time settings.
  7. Exit setup by pressing the right button until the three flashing dashes reappear.

How to Use the HemoCue® Hb 201+ System

Accurate capillary sampling is essential for obtaining reliable results with the HemoCue® Hb 201+ System. Follow these steps to ensure proper technique and measurement.

Preparation:

  • Ensure the cuvette holder is in the loading position (three flashing dashes).
  • Warm and relax the patient's hand.
  • Use the middle or ring finger (avoid rings).
  • Clean and dry the fingertip, then stimulate blood flow with light pressure.

Sample Collection:

  • Puncture the fingertip's side with a lancet.
  • Wipe away the first 2-3 drops, then collect the next.
  • Fill the microcuvette completely in one attempt–do not refill.
  • Wipe excess blood and check for bubbles. Discard if necessary.

Measurement:

  • Insert the filled microcuvette and push the holder to the measuring position.
  • View results while the holder remains in position.
  • Discard the microcuvette after use.
  • Access stored results via the scroll function.

Safety:

  • Wear gloves and handle blood samples carefully.
  • Follow local disposal guidelines.

HB 201+ Cleaning and Maintenance

Daily Cleaning of the Cuvette Holder:

  1. Turn Off the Analyzer – Press the power button to shut it down.
  2. Remove the Cuvette Holder – Pull it into the loading position and press the release mechanism.
  3. Clean the Inside Cover Glasses:
    • Insert a cleaning swab into the cuvette holder opening.
    • Move the swab gently side to side, then push it in and out.
    • If the swab gets dirty, use a fresh one to continue.

Cleaning the Exterior Surfaces:

  • Use a 20-70% alcohol solution or mild detergent to wipe down the cuvette holder and black housing components.

Reinstallation:

  • Allow 15 minutes for the cuvette holder to dry before reinstalling it.

Common Questions About the HemoCue® Hb 201+ System

Q: How accurate is the HemoCue® Hb 201+ System?

A: The device provides lab-quality accuracy, offering hemoglobin results that clinicians can trust, with built-in quality control checks.

Q: What kind of samples can be used with the system?

A: The Hb 201+ System can analyze capillary, venous, or arterial whole blood samples, giving medical professionals flexibility in various testing environments.

Q: Is calibration necessary?

A: No further calibration is needed as the system comes pre-calibrated against the international reference method for hemoglobin measurement, ensuring ongoing accuracy.

Q: How much blood is required for a test?

A: The system only requires approximately 10 µL of blood, making the sample size minimal for patient comfort.

Q: Can the HemoCue® Hb 201+ System be used outside a laboratory setting?

A: Yes, the system is designed for easy use by non-laboratory personnel, making it an ideal choice for point-of-care testing in clinics and other medical environments.


Sources: